MAINTENANCE Ash container
Maintenance
Ash removal
Placement
On the boiler´s side
Procedure
Check up the ash content in the container, empty it when
necessary.
Maitenance period
When necessaryd
Pos.
MAINTENANCE-01
Seitenansicht 0
1 2 3 4 5 6 ... 40 41

Inhaltsverzeichnis

Seite 1 - MAINTENANCE-01

MAINTENANCE Ash container Maintenance Ash removal Placement On the boiler´s side Procedure Check up the ash content in

Seite 2 - MAINTENANCE-02

MAINTENANCE Cleaning of suction blowers Maintenance Suction blower Placement Back side of the heating boiler Procedure Clean the suct

Seite 3 - MAINTENANCE-03

MAINTENANCE Cleaning of flue gas tube Maintenance Flue gas tube and chimney Placement Down the suction blower Procedure 1. Cl

Seite 4 - MAINTENANCE-04

CLEANING Compressor Maintenance Compressor Placement In the heating room near the switch box Procedure Empty the condensed wate

Seite 5 - MAINTENANCE-05a

CLEANING Maintenance Cleaning Place Heating room Procedure Cleaning of all motors and blowers Maintenance period Hal

Seite 6 - MAINTENANCE-05c

CLEANING Hydraulic aggregate Maintenance Hydraulic aggregate Placement In the heating room near the heating boiler Procedure

Seite 7 - MAINTENANCE-06a

LUBRICATION Silo discharge Maintenance Replacement of gear smear in the silo discharging system E

Seite 8 - MAINTENANCE-06c

LUBRICATIONCross feed worm screw Maitenance Lubrication of the flange bearings of cross feed worm screw Placement Behi

Seite 9 - MAINTENANCE-07

LUBRICATION Cross feed worm screw Maitenance Lubrication of the flange bearings of cross feed worm screw Placement

Seite 10 - MAINTENANCE-08

MAINTENANCE Hydraulic push rods Maintenance hydraulic aggregate 5. Check up of the oil l

Seite 11 - MAINTENANCE-09

MAITENANCE Hydraulic push rods Maintenance of hydraulic aggregate Check up of the cylinder and hoses tightn

Seite 12 - CLEANING-02

MAINTENANCE Igniter Maintenance Igniter Placement On the side of heating boiler procedure Unscrew the ignition tube a

Seite 13 - CLEANING-03

LUBRICATION PLAN conveyor Maintenance Lubrication of the worm screw flange bearing on the side of motor Placement Behind

Seite 14 - CLEANING-05

LUBRICATION Ash worm conveyor Multicyclone Maintenance Lubrication of bearings on the ash worm conveyor on multicyclone Plac

Seite 15 - LUBRICATION Silo discharge

LUBRICATION Ash conveying rising worm screw Maintenance Lubrication of rising worm screw bearing Maintenance Lubrication of bearing on

Seite 16 - PUSH R-01

LUBRICATION Grate ash removal Maintenance Lubrication of bearing on worm screw removing ash from grate Maintenance L

Seite 17

LUBRICATION Suction blowers Maintenance Lubrication of the bearing between the suction casing and the motor for suction blowers.

Seite 18

CLEANING Cleaning of heat exchanger Maitenance Cleaning of heat exchanger Placement Front side od heat exchanger

Seite 19 - MAITENANCE

CLEANING Compressor Maintenance Compressor Placement In the heating room near the switch box Procedure Empty the condensed wate

Seite 20 - WORM SCREW-01

CLEANING Maintenance Cleaning Place Heating room Procedure Cleaning of all motors and blowers Maintenance period Half

Seite 21 - LUBRIC-01

CLEANING Underpressure tube Maintenance Cleaning of the underpressure tube Placement Underpressure switch Procedure Pull the

Seite 22 - LUBRIC-02

CLEANING Hydraulic aggregate Maintenance Hydraulic aggregate Placement In the heating room near the heating boiler Procedure 8

Seite 23 - LUBRIC-03

CLEANING Multicyclone Maintenance Multicyclone Placement Maintenance cover on the side of heating boiler Procedure Open th

Seite 24 - LUBRIC-04

LUBRICATION Elbow discharge Maitenance Lubrication of the flange bearings of elbow discharging worm screw Placement Behind

Seite 25 - CLEANING-01

LUBRICATION Elbow discharge Maintenance Replacement of the gear oil in the elbow discharge system Emptying of silo i

Seite 27

Notices: Gear motors – Oil replacement, periods, inbuilt parts, filling quantities, venting screws, filling openings, oil condition considering...

Seite 28 - CLEANING -04

MAINTENANCE AND LUBRICATIONS PLAN Maintenance You have bought Gilles heating facility – that means, you have obtained solid equ

Seite 29

Lubricated places The remarked lubricated places must be lubricated ca. once a month (every 200 operation hours). Use pressure oilers for greasing s

Seite 30 - ELBOW-01

1 2 Consistency mark (NLGI- classes acc. DIN 51813 Fulling penetration specified according units DIN ISO 21371) 000 445 to 475 00 400 to 430 0 35

Seite 31 - ELBOW-02

Additional marks for synthetic oils E Organic esters EF Perfluorine - fluids HC Synthetic hydrocarbons PH Esters of phosphoric acid PG Polyglycol oi

Seite 32

Operation and maitenance logbook Operation hours Cleaning Date Time <60% >60% Output % Course T°C Combustion T°C Flue gas

Seite 33 - Notices:

Maintenace Gilles - Heating facility Date: Facility: Customer: Only qualified skilled personal may carry out the maintenance works,

Seite 34 - Maintenance

MAINTENANCE Ash removal from rost Maintenance Ash removal from rost Placement On the heating boiler´s back side, near the stock

Seite 35 - Lubrication greases

21 Lubrication of the worm screw bearing ELBOW DISCHARGE - maintenance quarterly half a year once a year Funct. Carried out 1 Lubrication o

Seite 36

Maintenance Gilles-heating facility Date: Annexes Customer: Lubricants – greasing 1 Multicyclone ash removing worm screw 2 Ash rising worm s

Seite 37

MAINTENANCE Cleaning of the combustion chamber Maintenance Combustion chamber UTSK- under stocker Placement ‚Front s

Seite 38

MAINTENANCE Cleaning of combustion chamber Maintenance Combustion chamber UTSK- step grate Placement ‚Front side of the heating boil

Seite 39

MAINTENANCE Cleaning of burning grate Maintenance Burning grate UTSK- understocker Placement Front side of the heating boil

Seite 40

MAINTENANCE Cleaning of burning grate Maintenance Burning grate UTSK-Step grate Placement Front side of the heating boiler

Seite 41

MAINTENANCE Cleaing of heat exchanger Maintenance Heat exchanger Placement Front side of the heating boiler Procedure